Require active scan
Table of contents
Support for additional sensors can be requested by opening an issue.
Check the Senor Request page on how to provide useful information for adding new sensors.
NOTE: Properties with a *
have additional information in the device notes.
Require Active Scan to be enabled
Air Mentor Air Mentor 2S
Air Mentor 2S Connected 7-in-1 Air Quality Monitor
temperature
temperature calibrated
humidity
tvoc
formaldehyde
aqi
air quality
CO2
PM2.5
PM10
rssi
Triangual body, no screen
- Active Scan required
- true
Notes:
- aqi is the Air Quality Index, represented as a number. More information about this index can be found on https://www.airnow.gov/aqi/aqi-basics/
Air Mentor Air Mentor Pro 2
Air Mentor PRO 2 6-in-1 Indoor Air Quality Monitor
temperature
temperature calibrated
humidity
tvoc
aqi
air quality
CO2
PM2.5
PM10
rssi
Triangual body, no screen
- Active Scan required
- true
Notes:
- aqi is the Air Quality Index, represented as a number. More information about this index can be found on https://www.airnow.gov/aqi/aqi-basics/
Apple iBeacon
iBeacon
cypress temperature *
cypress humidity *
rssi
measured power
uuid *
mac
major
minor
- Active Scan required
- true
Notes:
- cypress temperature This sensor is disabled by default and can be turned on in the device menu. Measured in °C. Calculated based on minor
175.72 * ((minor & 0xff) * 256) / 65536 - 46.85
- cypress humidity This sensor is disabled by default and can be turned on in the device menu. Measured in RH%. Calculated based on minor
125.0 * (minor & 0xff00) / 65536 - 6
- uuid This sensor is disabled by default and can be turned on in the device menu.
- iBeacon is not a device, but a protocol developed by Apple on which beacons work, for example Apple AirTags.
- It should not be used for tracking
MAC addresses
, they can be dynamic, there is aBeacon UUID
parameter for this.
Chef iQ CQ60
Wireless Meat Thermometer
temperature probe tip *
temperature probe *
ambient temperature *
meat temperature *
rssi
pen-shaped probe.
- Active Scan required
- true
Notes:
- temperature probe tip The probe has multiple temperature sensors.
temperature probe tip
is the sensor at the ring closest to the tip of the probe. - temperature probe
temperature probe 1, 2 and 3
are the sensors at the other rings, where 1 is the ring next to the ring at the tip of the probe and 3 is the ring closest to the black end of the probe. Note that all sensors are broadcasting temperature with 1 digit, only temperature probe 3 is broadcasting temperature with 0 digits (before averaging in BLE monitor). - ambient temperature
ambient temperature
is the sensor in the black part of the probe. Note that there seems to be an upper limit for the broadcasted ambient temperature. - meat temperature
meat temperature
is the minimum oftemperature probe tip
,temperature probe 1
andtemperature probe 2
.
Govee H5051
Thermometer Hygrometer (BLE only)
temperature
humidity
battery
rssi
Oval body, LCD screen
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5055
Smart Meat Thermometer
temperature probe
temperature alarm probe
battery
rssi
Square body, with 6 probes.
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5071
Thermometer Hygrometer (BLE only)
temperature
humidity
battery
rssi
Oval body, LCD screen
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5072
Thermometer Hygrometer
temperature
humidity
battery
rssi
Oval body, LCD screen.
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5074
Thermometer Hygrometer
temperature
humidity
battery
rssi
Square body, no screen.
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5075
Thermometer Hygrometer
temperature
humidity
battery
rssi
Rounded square body, LCD screen
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5101/H5102
Thermometer Hygrometer
temperature
humidity
battery
rssi
Rounded square body, LCD screen
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5106
Thermometer Smart Air Quality Monitor
temperature
humidity
pm2.5
rssi
Rounded rectangular body with screen
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5177
Thermometer Hygrometer
temperature
humidity
battery
rssi
Rounded square body, Backlight LCD Touchscreen
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5178
Indoor/Outdoor Thermometer Hygrometer
temperature
humidity
battery
rssi
Rounded square body, Backlight LCD Touchscreen with additional rounded rectangular remote sensor for outdoor measurements.
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work. Note that two devices will be created in Home Assistant for this sensor, one with the actual MAC address, which is the indoor sensor, and one with the MAC address increased by 1, which is the outdoor sensor. You can also distinguish between the indoor and outdoor sensor by looking at the device type.
Govee H5179
Thermometer Hygrometer (BLE only)
temperature
humidity
battery
rssi
Square body, no screen.
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5182
Smart Meat Thermometer
temperature probe
temperature alarm probe
rssi
Square body, with 2 probes.
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5183
Meat Thermometer
temperature probe
temperature alarm probe
rssi
Square body, with probe.
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5184
Smart Meat Thermometer
temperature probe
temperature alarm probe
rssi
Square body, with 4 probes.
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5185
Smart Meat Thermometer
temperature probe
temperature alarm probe
rssi
Square body, with 2 probes.
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5198
Grilling Meat Thermometer
temperature probe
temperature alarm probe
low temperature alarm probe
rssi
Square body, with 4 probes.
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Inkbird IBS-TH1
Inkbird IBS-TH1
temperature
temperature probe 1 *
humidity *
battery
rssi
- Active Scan required
- true
Notes:
- temperature probe 1 The external temperature probe is only available on the plus version of the Inkbird sensor. When the external probe is connected, the sensor will stop reporting the internal temperature.
- humidity Humidity is only reported by the internal sensor.
Inkbird IBS-TH2
Inkbird IBS-TH2
temperature
temperature probe 1 *
humidity *
battery
rssi
- Active Scan required
- true
Notes:
- humidity Some IBS-TH2 devices are not sending humidity data, only temperature. Both are sold as IBS-TH2. Sensors that only send temperature will be recognized as IBS-TH2/P01R in BLE monitor, the ones with humidity as IBS-TH.
- temperature probe 1 The external temperature probe is only available on the plus version of the Inkbird sensor. When the external probe is connected, the sensor will stop reporting the internal temperature.
Jaalee JHT
Temperature & Humidity sensor
temperature
humidity
battery
rssi
Square rounded body
- Active Scan required
- true
- Broadcast Rate
- ~1/sec.
Kegtron KT-100
KT-100
keg size
volume start
port state
port index
port count
port name
volume dispensed port 1
rssi
- Active Scan required
- true
Kegtron KT-200
KT-200
keg size
volume start
port state
port index
port count
port name
volume dispensed port 1
volume dispensed port 2
rssi
- Active Scan required
- true
KKM K6
Temperature/Humidity Sensor Beacon K6
temperature
humidity
acceleration
battery
voltage
rssi
- Active Scan required
- true
Moat S2 Smart Temperature & Humidity Sensor
Moat S2
temperature
humidity
battery
rssi
Square rounded body.
- Active Scan required
- true
Notes:
- Sensor has been added based on information from https://github.com/SteveOnorato/moat_temp_hum_ble. It has not been confirmed that the sensor is working correct. Please leave an message in an new issue to confirm if it is working.
Radius Networks AltBeacon
AltBeacon
rssi
measured power
uuid
mac
major
minor
- Active Scan required
- true
Notes:
- AltBeacon is not a device, but a protocol developed by AltBeacon on which beacons work.
- It should not be used for tracking
MAC addresses
, they can be dynamic, there is aBeacon UUID
parameter for this.
Switchbot Meter TH plus
Thermometer and Hygrometer
temperature
humidity
battery
rssi
Rounded square body, LCD screen
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Switchbot Meter TH S1
Thermometer and Hygrometer
temperature
humidity
battery
rssi
Rounded square body, LCD screen
- Active Scan required
- true
Notes:
- actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Xiaomi Mi Band 4 and 5
Mi Band
heart rate
steps
rssi
Oval Watch
- Active Scan required
- true
Notes:
- The Mi Band also reports
steps
, but this requires you to turn on active scan.