Link Search Menu Expand Document

Require active scan


Table of contents

Support for additional sensors can be requested by opening an issue.
Check the Senor Request page on how to provide useful information for adding new sensors.

NOTE: Properties with a * have additional information in the device notes.

Require Active Scan to be enabled


Air Mentor Air Mentor 2S
Air Mentor 2S Connected 7-in-1 Air Quality Monitor
temperature
temperature calibrated
humidity
tvoc
formaldehyde
aqi
air quality
CO2
PM2.5
PM10
rssi
Air Mentor 2S
Triangual body, no screen
Active Scan required
true
Notes:
  • aqi is the Air Quality Index, represented as a number. More information about this index can be found on https://www.airnow.gov/aqi/aqi-basics/
Air Mentor Air Mentor Pro 2
Air Mentor PRO 2 6-in-1 Indoor Air Quality Monitor
temperature
temperature calibrated
humidity
tvoc
aqi
air quality
CO2
PM2.5
PM10
rssi
Air Mentor Pro 2
Triangual body, no screen
Active Scan required
true
Notes:
  • aqi is the Air Quality Index, represented as a number. More information about this index can be found on https://www.airnow.gov/aqi/aqi-basics/
Apple iBeacon
iBeacon
cypress temperature *
cypress humidity *
rssi
measured power
uuid *
mac
major
minor
iBeacon
Active Scan required
true
Notes:
  • cypress temperature This sensor is disabled by default and can be turned on in the device menu. Measured in °C. Calculated based on minor 175.72 * ((minor & 0xff) * 256) / 65536 - 46.85
  • cypress humidity This sensor is disabled by default and can be turned on in the device menu. Measured in RH%. Calculated based on minor 125.0 * (minor & 0xff00) / 65536 - 6
  • uuid This sensor is disabled by default and can be turned on in the device menu.
  • iBeacon is not a device, but a protocol developed by Apple on which beacons work, for example Apple AirTags.
  • It should not be used for tracking MAC addresses, they can be dynamic, there is a Beacon UUID parameter for this.
Chef iQ CQ60
Wireless Meat Thermometer
temperature probe tip *
temperature probe *
ambient temperature *
meat temperature *
rssi
CQ60
pen-shaped probe.
Active Scan required
true
Notes:
  • temperature probe tip The probe has multiple temperature sensors. temperature probe tip is the sensor at the ring closest to the tip of the probe.
  • temperature probe temperature probe 1, 2 and 3 are the sensors at the other rings, where 1 is the ring next to the ring at the tip of the probe and 3 is the ring closest to the black end of the probe. Note that all sensors are broadcasting temperature with 1 digit, only temperature probe 3 is broadcasting temperature with 0 digits (before averaging in BLE monitor).
  • ambient temperature ambient temperature is the sensor in the black part of the probe. Note that there seems to be an upper limit for the broadcasted ambient temperature.
  • meat temperature meat temperature is the minimum of temperature probe tip, temperature probe 1 and temperature probe 2.
Govee H5051
Thermometer Hygrometer (BLE only)
temperature
humidity
battery
rssi
H5051
Oval body, LCD screen
Active Scan required
true
Notes:
  • actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5071
Thermometer Hygrometer (BLE only)
temperature
humidity
battery
rssi
H5071
Oval body, LCD screen
Active Scan required
true
Notes:
  • actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5072
Thermometer Hygrometer
temperature
humidity
battery
rssi
H5072
Oval body, LCD screen.
Active Scan required
true
Notes:
  • actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5074
Thermometer Hygrometer
temperature
humidity
battery
rssi
H5074
Square body, no screen.
Active Scan required
true
Notes:
  • actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5075
Thermometer Hygrometer
temperature
humidity
battery
rssi
H5075
Rounded square body, LCD screen
Active Scan required
true
Notes:
  • actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5101/H5102
Thermometer Hygrometer
temperature
humidity
battery
rssi
H5101/H5102
Rounded square body, LCD screen
Active Scan required
true
Notes:
  • actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5106
Thermometer Smart Air Quality Monitor
temperature
humidity
pm2.5
rssi
H5106
Rounded rectangular body with screen
Active Scan required
true
Notes:
  • actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5177
Thermometer Hygrometer
temperature
humidity
battery
rssi
H5177
Rounded square body, Backlight LCD Touchscreen
Active Scan required
true
Notes:
  • actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5178
Indoor/Outdoor Thermometer Hygrometer
temperature
humidity
battery
rssi
H5178
Rounded square body, Backlight LCD Touchscreen with additional rounded rectangular remote sensor for outdoor measurements.
Active Scan required
true
Notes:
  • actve scan needs to be enabled in the BLE Monitor settings for this sensor to work. Note that two devices will be created in Home Assistant for this sensor, one with the actual MAC address, which is the indoor sensor, and one with the MAC address increased by 1, which is the outdoor sensor. You can also distinguish between the indoor and outdoor sensor by looking at the device type.
Govee H5179
Thermometer Hygrometer (BLE only)
temperature
humidity
battery
rssi
H5179
Square body, no screen.
Active Scan required
true
Notes:
  • actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5182
Smart Meat Thermometer
temperature probe
temperature alarm probe
rssi
H5182
Square body, with 2 probes.
Active Scan required
true
Notes:
  • actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5183
Meat Thermometer
temperature probe
temperature alarm probe
rssi
H5183
Square body, with probe.
Active Scan required
true
Notes:
  • actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5184
Smart Meat Thermometer
temperature probe
temperature alarm probe
rssi
H5184
Square body, with 4 probes.
Active Scan required
true
Notes:
  • actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5185
Smart Meat Thermometer
temperature probe
temperature alarm probe
rssi
H5185
Square body, with 2 probes.
Active Scan required
true
Notes:
  • actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Govee H5198
Grilling Meat Thermometer
temperature probe
temperature alarm probe
low temperature alarm probe
rssi
H5198
Square body, with 4 probes.
Active Scan required
true
Notes:
  • actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Inkbird IBS-P01B
Inkbird Pool Thermomenter
temperature
battery
rssi
IBS-P01B
Active Scan required
true
Inkbird IBS-TH1
Inkbird IBS-TH1
temperature
temperature probe 1 *
humidity *
battery
rssi
IBS-TH1
Active Scan required
true
Notes:
  • temperature probe 1 The external temperature probe is only available on the plus version of the Inkbird sensor. When the external probe is connected, the sensor will stop reporting the internal temperature.
  • humidity Humidity is only reported by the internal sensor.
Inkbird IBS-TH2
Inkbird IBS-TH2
temperature
temperature probe 1 *
humidity *
battery
rssi
IBS-TH2
Active Scan required
true
Notes:
  • humidity Some IBS-TH2 devices are not sending humidity data, only temperature. Both are sold as IBS-TH2. Sensors that only send temperature will be recognized as IBS-TH2/P01R in BLE monitor, the ones with humidity as IBS-TH.
  • temperature probe 1 The external temperature probe is only available on the plus version of the Inkbird sensor. When the external probe is connected, the sensor will stop reporting the internal temperature.
Jaalee JHT
Temperature & Humidity sensor
temperature
humidity
battery
rssi
JHT
Square rounded body
Active Scan required
true
Broadcast Rate
~1/sec.
Kegtron KT-100
KT-100
keg size
volume start
port state
port index
port count
port name
volume dispensed port 1
rssi
KT-100
Active Scan required
true
Kegtron KT-200
KT-200
keg size
volume start
port state
port index
port count
port name
volume dispensed port 1
volume dispensed port 2
rssi
KT-200
Active Scan required
true
KKM K6
Temperature/Humidity Sensor Beacon K6
temperature
humidity
acceleration
battery
voltage
rssi
K6
Active Scan required
true
Moat S2 Smart Temperature & Humidity Sensor
Moat S2
temperature
humidity
battery
rssi
S2 Smart Temperature & Humidity Sensor
Square rounded body.
Active Scan required
true
Notes:
  • Sensor has been added based on information from https://github.com/SteveOnorato/moat_temp_hum_ble. It has not been confirmed that the sensor is working correct. Please leave an message in an new issue to confirm if it is working.
Oras Faucet
Oras Electra Washbasin Faucet
rssi
battery
Faucet
Active Scan required
true
Radius Networks AltBeacon
AltBeacon
rssi
measured power
uuid
mac
major
minor
AltBeacon
Active Scan required
true
Notes:
  • AltBeacon is not a device, but a protocol developed by AltBeacon on which beacons work.
  • It should not be used for tracking MAC addresses, they can be dynamic, there is a Beacon UUID parameter for this.
Switchbot Meter TH plus
Thermometer and Hygrometer
temperature
humidity
battery
rssi
Meter TH plus
Rounded square body, LCD screen
Active Scan required
true
Notes:
  • actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Switchbot Meter TH S1
Thermometer and Hygrometer
temperature
humidity
battery
rssi
Meter TH S1
Rounded square body, LCD screen
Active Scan required
true
Notes:
  • actve scan needs to be enabled in the BLE Monitor settings for this sensor to work.
Xiaomi Mi Band 4 and 5
Mi Band
heart rate
steps
rssi
Mi Band 4 and 5
Oval Watch
Active Scan required
true
Notes:
  • The Mi Band also reports steps, but this requires you to turn on active scan.